P.O. Box 180 - Garvin, OK 74736 - 580-286-7047 Fax 580-286-4268
Typical Electropherograms:
SeaQuate SQL 4250:
4.25% gel solution run with ABI 377. These gel electropherograms are provide
courtsey of Dr. Bruce Roe of the University of Oklahoma Genome Sequencing
Center, Chemistry Department, Norman, Oklahoma USA
Additional Examples | ||
| Photo 1 | Photo 2 | Photo 3 |
SeaQuate SQL 4250:
4.25% gel solution run with ABI 377. Electropherograms are provided courtsey
of Dr. Christiana Robbins and Dr. Eric Green of the National Institute of
Health, National Human Genome Sequencing Center, Bethesda, Maryland USA
SeaQuate SQL 4750:
The gel solution chosen by Washington University Genome Sequencing Center
for use with the ABI 373S in mapping the Merck EST mapping project for the
public data base. Electropherograms are provided courtsey of Dr. Richard
Wilson and Dr. Elaine Mardis Washington University Genome Seqiuencing Center
St Louis, Missouri USA
Additional Examples | |
| Photo 1 | Photo 2 |
SeaQuate SQL 5500:
5.5% gel solution run ABI 377 . Electropherograms are provided courtsey
of Dr. Christiana Robbins and Dr. Eric Green of the National Institute of
Health, National Human Genome Sequencing Center, Bethesda, Maryland USA
Additional Examples | ||
| Photo 1 | Photo 2 | Photo 3 |
SeaQuate SQL 6500:
6.5% gel solution run with ABI 373A. This gel solution provides better resolution
and longer read length when compaired to the standard 6% gel solution normally
used with the ABI 373. Electroperograms are provide courtsey of Dr. Donna
Muzny and Dr. Richard Gibbs of the Baylor College of Medicine Genome Sequencing
Center, Houston, Texas USA
Additional Examples | |
| Photo 1A | Photo 1B |
See How Easy DNA Sequencing Can Be!
With SeaQuate DNA sequencing Gel Solution you avoid mixing, measuring and
mess because the solution comes to you in 1 premixed bottle containing TEMED,
urea, TBE and acrylamide. Just add APS and pour. So from start to finish
your gel is ready to run in 30 minutes.
Safe:
The liquid format of Sooner Scientific's SeaQuate DNA Sequencing Solution
eliminates the safety hazards of dry acrylamide.
Reproducible Results:
Each lot of SeaQuate DNA Sequencing Gel Solution is first tested and qualified
in the Sooner Scientific QC lab for conductivity, pH and refractive index.
Then a test sequencing gel is run to ensure band sharpness and migration.
All this adds confidence; confidence that you will get consistent, reproducible,
quality results time after time.
Kit Contents:
SQL 4001 4.00% SeaQuate Gel Solution (1x), 6M Urea*1.0 L.
SQL 4250 4.25% SeaQuate Gel Solution (1x), 6M Urea*1.0 L.
SQL 4302 4.00% SeaQuate Gel Solution (1x), 8.3M Urea*1.0 L.
SQL 4750 4.75% SeaQuate Gel Solution (1x), 8.3M Urea 1.0 L.
SQL 5500 5.50% SeaQuate Gel Solution (1x), 8.3M Urea1.0 L.
SQL 6500 6.50% SeaQuate Gel Solution (1x), 8.3M Urea1.0 L.
SQL 4301 4.00% SeaQuate Gel Solution (1x), 7M Urea1.0 L.
SQL 5301 5.00% SeaQuate Gel Solution (1x), 7M Urea1.0 L.
SQL 6301 6.00% SeaQuate Gel Solution (1x), 7M Urea1.0 L
SQL 8301 8.00% SeaQuate Gel Solution (1x), 7M Urea1.0 L
XLRSQL 4000 4.00% SeaQuate Gel Solutions 29:1 (1x),1.0L 6M Urea
XLRSQL 4250 4.25% SeaQuate Gel Solutions 29:1 (1x),1.0L 6M Urea
XLRSQL 4500 4.50% SeaQuate Gel Solutions 29:1 (1x),1.0L 6M Urea
XLRSQL 5000 5.00% SeaQuate Gel Solutions 29:1 (1x),1.0L 6M Urea
XLRSQL 4750 4.75% SeaQuate Gel Solutions 29:1 (1x),1.0L 8.3M Urea
XLRSQL 6301 6.00% SeaQuate Gel Solutions 29:1 (1x),1.0L 7M Urea
* Temed and APS must be added to these formulas.
Storage:
For best performance keep frozen until opening. After opening store at 4C
in the dark.
Stability:
5 months in the dark, at 4C.
Preparation:
References:
Ordering/Price Information - Please see page 38 or the index.
<-previous page | next page->
| Home | Information | What's New | E-mail Us |